AIRLINK 79.41 Increased By ▲ 1.02 (1.3%)
BOP 5.33 Decreased By ▼ -0.01 (-0.19%)
CNERGY 4.38 Increased By ▲ 0.05 (1.15%)
DFML 33.19 Increased By ▲ 2.32 (7.52%)
DGKC 76.87 Decreased By ▼ -1.64 (-2.09%)
FCCL 20.53 Decreased By ▼ -0.05 (-0.24%)
FFBL 31.40 Decreased By ▼ -0.90 (-2.79%)
FFL 9.85 Decreased By ▼ -0.37 (-3.62%)
GGL 10.25 Decreased By ▼ -0.04 (-0.39%)
HBL 117.93 Decreased By ▼ -0.57 (-0.48%)
HUBC 134.10 Decreased By ▼ -1.00 (-0.74%)
HUMNL 7.00 Increased By ▲ 0.13 (1.89%)
KEL 4.67 Increased By ▲ 0.50 (11.99%)
KOSM 4.74 Increased By ▲ 0.01 (0.21%)
MLCF 37.44 Decreased By ▼ -1.23 (-3.18%)
OGDC 136.70 Increased By ▲ 1.85 (1.37%)
PAEL 23.15 Decreased By ▼ -0.25 (-1.07%)
PIAA 26.55 Decreased By ▼ -0.09 (-0.34%)
PIBTL 7.00 Decreased By ▼ -0.02 (-0.28%)
PPL 113.75 Increased By ▲ 0.30 (0.26%)
PRL 27.52 Decreased By ▼ -0.21 (-0.76%)
PTC 14.75 Increased By ▲ 0.15 (1.03%)
SEARL 57.20 Increased By ▲ 0.70 (1.24%)
SNGP 67.50 Increased By ▲ 1.20 (1.81%)
SSGC 11.09 Increased By ▲ 0.15 (1.37%)
TELE 9.23 Increased By ▲ 0.08 (0.87%)
TPLP 11.56 Decreased By ▼ -0.11 (-0.94%)
TRG 72.10 Increased By ▲ 0.67 (0.94%)
UNITY 24.82 Increased By ▲ 0.31 (1.26%)
WTL 1.40 Increased By ▲ 0.07 (5.26%)
BR100 7,526 Increased By 32.9 (0.44%)
BR30 24,650 Increased By 91.4 (0.37%)
KSE100 71,971 Decreased By -80.5 (-0.11%)
KSE30 23,749 Decreased By -58.8 (-0.25%)

imageISLAMABAD: The 147 mw capacity Patrind Hydropower Project would be completed in year 2017 with the cost of US 362 million.

The run-of-river Patrind Hydropower Project is being constructed on river Kunhar. The project will generate, on average, 632.6 GWh of electricity annually.

Since the project is being developed by SHPL as an IPP, the SHPL has entered into a 30 year Power Purchase Agreement with National Transmission and Despatch Company (NTDC), Pakistan's gird system operator, for the sale of electricity generated from the Project.

The project is located on the boundary of Azad Jammu & Kashmir (AJ&K) and District Abbottabad of Pakistan, near Muzaffarabad. The majority of the project structures, including the powerhouse, are located in the territory of AJ&K.

However, the diversion tunnel will be located within territorial limits of District Abbottabad.

The project is located on right side of river Kunhar at a distance of approximately 12.3 km from Garhi Habibullah. The powerhouse side of the project is accessible from lower Chattar, Muzaffarabad where a new 70 bridge has been constructed across river Jhelum as part of the Project.

The plan of the project is to divert the waters of river Kunhar through a weir, located near village Patrind, and a left bank conveyance system of sandtrap and tunnels to the right bank of river Jhelum, near the city of Muzaffarabad, where a powerhouse will be built.

The natural difference of elevation between river Kunhar and river Jhelum, along with a 42 meter high weir provides a gross head of 114.5 meters to set up a 147MW power project.

Major project components envisaged under the proposed scheme include a weir structure within the river Kunhar, an intake structure slightly upstream of the weir leading, through a dual-chamber sandtrap, to the headrace tunnel.

The headrace tunnel passes through the Lohar Gali ridge towards the river Jhelum. It opens into an underground surge tank at the start of a vertical pressure shaft, that connects with a horizontal pressure tunnel (penstock). The penstock divides into three manifolds conveying design discharge to a surface type powerhouse located on the right bank of the river Jhelum.

The crest elevation is 757 masl which is approximately 26m high from the river bed. There will be two radial type crest gates and two under sluice gates for carrying out flushing. The weir will also accommodate a bridge having deck at elevation 769 masl. Which will provide easy access to the local community and by providing a connection between AJ&K and Khyber Pakhtunkhwa.

The intake block is located on the left bank of river Kunhar just upstream of the weir. Two intake gates are provided having dimensions of W12 m x H9 m. The facility is also equipped with trashracks.

The sandtrap system consists of the two chambers, each of 135 m length. The retaining sediment grain size is > 0.20 mm.

From the sandtrap a headrace tunnel of 7.0 m internal diameter and a length of 2.2 km, will lead to the surge tank.

Concrete lined underground surge tank is proposed at the start of vertical pressure shaft to control water hammer.

A pressure shaft 79.5 m high and 7.0 m in diameter is proposed in hill mass on the right bank of river Jhelum. The penstock divides into three manifolds, having diameter of 3.2 m each.

A surface type powerhouse to accommodate three vertical Francis turbine units, each of 50 MW capacity, is proposed on the right bank of river Jhelum. The powerhouse site is about 8.52 km upstream of the Kunhar - Jhelum confluence.

A Gas Insulated Switchgear (GIS) system is proposed to be constructed on the right bank of river Jhelum. The power from the project will be evacuated through 132 KV double circuit transmission line.